\Çy|Ç|àx fxÜ|xá
Model Numbers: MQRB4436, MQRB5143, MQRB6961
Stock Numbers: MQRB4436N, MQRB4436NE, MQRB4436LP, MQRB4436LPE
MQRB5143N, MQRB5143NE, MQRB5143LP, MQRB5143LPE
MQRB6961N, MQRB6961NE, MQRB6961LP, MQRB6961LPE
Installation Instructions
Certified to: ANSI Z21.50b-2009, CSA 2.22b-2009, CGA 2.17-M91
“Zero Clearance”
Direct Vent Gas Fireplace
Read this complete manual before beginning installation.
These instructions must be kept with the unit for future reference.
For Your Safety
A Division of R-Co. Inc. * 2340 Logan Ave. * Winnipeg, Manitoba * Canada * R2R 2V3
Printed in Canada October 9, 2012, Part# 51MQ-MAN-PVH
WARNING: If the information in these instructions is not followed exactly, a fire
or explosion may result causing property damage, personal injury or loss of life.
Warning: Improper installation, adjustment, alteration, service or maintenance can cause property damage,
personal injury or loss of life. Refer to this manual. Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Extinguish any open flame.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone.
If you cannot reach your gas supplier, call the fire department.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not
convertible for use with other
g
ases
,
unless a certified kit is used.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA only) or
mobile home, where not prohibited by local codes. This
appliance is only for use with the type(s) of gas indicated
on the rating plate. A conversion kit is supplied with the
appliance.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
WARNING
HOT GLASS WILL
CAUSE BURNS
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
Vue de la page 0
1 2 3 4 5 6 ... 115 116

Résumé du contenu

Page 1 - \Çy

\Çy|Ç|àx fxÜ|xá Model Numbers: MQRB4436, MQRB5143, MQRB6961 Stock Numbers: MQRB4436N, MQRB4436NE, MQRB4436LP, MQRB4436LPE MQR

Page 2 - Table of Contents

MQRB4436: Framing Your Gas Fireplace This section is intended for qualified installers only. Before beginning, make note of where the gas and electric

Page 3

PVH58 IPI SYSTEM CONNECTIONS Cold Climate Switch Must Be Disconnected From IPI Wiring Harness. Remove Batteries From Battery Ba

Page 4

*In the U.S.A. Thermostats are not permitted for Vented Gas Fireplaces (ANSI Z21.50b-2009 -Decorative). The above diagram shows how the Power Vent

Page 5 - Operating Instructions

PVCM Schematic - IPI 102

Page 7

PVH58 Air Intake Adjustment The PVH58 is shipped with the air intake adjustment fully closed. This will produce maximum draw at the fireplace. L

Page 8 - Massachusetts

PVH58 Troubleshooting NOTE: Before connecting Power Vent Control Module, ensure that all other systems and accessories (Remote Control, Fan, Light

Page 9 - -Fireplace to be covered

PVH58 Parts List PVH58 HORIZONTAL POWER VENT TERMINATION: Listed for Canada and USA NUMBER DESCRIPTION MQRB4436 AND MQRB5143 VENTING AND VENTING AD

Page 10 - Framing Your Gas Fireplace

58PVH-P3211 3/4” K.O. Bushing 58PVH-WTA Wall Thimble Assembly PVH20H Main Wiring Harness Assembly – Extension Harness (20ft) PVC58MV Power Vent Con

Page 11

MQRB4436 -Parts List Marquis Infinite Zero Clearance Direct Vent Gas Fireplace -44” Wide Listed for USA/Canada as a Decorative Appliance: Linear LH Bu

Page 12 - MQRB4436 -See Thru Framing

4436MQ-BLPSIE Burner Assembly- Liquid Propane c/w Valve System (MQRB4436LPE) 4436MQ-BNGSIE Burner Assembly-Natural Gas c/w Valve System (MQRB44

Page 13

MQRB4436 Locating Your Appliance All units are Factory Set for a Left Hand Burner System. Right Hand Burner System Requires Valve to be relocated to

Page 14

MQRB5143 -Parts List Marquis Infinite Zero Clearance Direct Vent Gas Fireplace -51” Wide Listed for USA/Canada as a Decorative Appliance: Linear LH Bu

Page 15

5143MQ-BNGSI Burner Assembly-Natural Gas c/w Valve System (MQRB5143N) 5143MQ-BLPSIE Burner Assembly- Liquid Propane c/w Valve System (MQRB5143LPE

Page 16

MQRB6961-Parts List Marquis Infinite Zero Clearance Direct Vent Gas Fireplace -69” Wide Listed for USA/Canada as a Decorative Appliance: Linear LH Bur

Page 17 - Surround Clearances MQRB4436

6961MQ-BLPSI Burner Assembly- Liquid Propane c/w Valve System (MQRB6961LP) 6961MQ-BNGSI Burner Assembly-Natural Gas c/w Valve System (MQRB6961N) 696

Page 18

Common Parts for MQRB4436, MQRB5143 and MQRB6961 Accessories Z1MT Thermostat (Not permitted for vented gas fireplaces installed in the U.S.A.) Milli

Page 19 - MQRB4436 Mantel Clearances

Valve System Parts 1000-P136WR Thermopile GOAI-524 1001-P069SI Electrode Sparker OFP42SA Spark Assist 1001-P216SI Thermocouple 290.216TC SIT 1001-P16

Page 20

This Limited Lifetime Warranty applies only while the unit remains at the site of the original installation and only if the unit is installed insi

Page 21 - Right Burner System

MQRB4436 -See Thru Framing An MQRB4436SK Kit is required for a See Thru Installation. Before you begin Framing- Determine for both sides whether the W

Page 22 - MQRB5143 -See Thru Framing

Wall Surface Flush With Face of Fireplace Framing Flush With Face of Fireplace Note: If using Optional Surround, Maximum Thickness for N

Page 23

MQRB4436 Single Sided Framing An MQRB4436BK Kit is required for a Single Sided Installation. Before you begin Framing- Determine whether the Wall Surf

Page 24

Wall Surface Flush With Face of Fireplace Framing Flush With Face of Fireplace Note: If using Optional Surround, Maximum Thickness for Non-

Page 25

MQRB4436 Combustible Enclosure Heights Cold Climate Recommendation When installing this fireplace against an exterior wall or chase, it is recommended

Page 26

Surround Dimensions MQRB4436 • The Surround Frames are 1” thick, with a 3/4” space behind the frame. • When using Surrounds, Maximum Thickness fo

Page 27 - Surround Clearances MQRB5143

MQRB4436 Facing Material Requirements These specifications are the same for all Models (4436N, 4436NE, 4436LP, 4436LPE). Note: If using Optional Surro

Page 28

MQRB4436 Mantel Clearances Before installing any mantels it is important to determine the combustibility of its material(s). There are two types of m

Page 29 - MQRB5143 Mantel Clearances

Table of Contents Table of Contents...

Page 30

MQRB5143: Framing Your Gas Fireplace This section is intended for qualified installers only. Before beginning, make note of where the gas and electric

Page 31

MQRB5143 Locating Your Appliance All units are Factory Set for a Left Hand Burner System. Right Hand Burner System Requires Valve to be relocated to r

Page 32 - MQRB6961 See Thru Framing

MQRB5143 -See Thru Framing An MQRB5143SK Kit is required for a See Thru Installation. Before you begin Framing- Determine for both sides whether the W

Page 33 - 19-3/8”

Wall Surface Flush With Face of Fireplace Framing Flush With Face of Fireplace Note: If using Optional Surround, Maximum Thickness for N

Page 34

MQRB5143 Single Sided Framing An MQRB5143BK Kit is required for a Single Sided Installation. Before you begin Framing- Determine whether the Wall Surf

Page 35 - Steel Framing Stud

Wall Surface Flush With Face of Fireplace Framing Flush With Face of Fireplace Note: If using Optional Surround, Maximum Thickness for Non-

Page 36

MQRB5143 Combustible Enclosure Heights Cold Climate Recommendation When installing this fireplace against an exterior wall or chase, it is recommende

Page 37 - Surround Clearances MQRB6961

Surround Dimensions MQRB5143 • The Surround Frames are 1” thick, with a 3/4” space behind the frame. • When using Surrounds, Maximum Thickness

Page 38

MQRB5143 Facing Material Requirements These specifications are the same for all Models (5143N, 5143NE, 5143LP, 5143LPE). Note: If using Optional Surr

Page 39 - MQRB6961 Mantel Clearances

MQRB5143 Mantel Clearances Before installing any mantels it is important to determine the combustibility of its material(s). There are two types of

Page 40 - (Continued…)

MQRB5143 Burner Section: Gas Conversion...

Page 41 - Panel Installation:

MQRB6961: Framing Your Gas Fireplace This section is intended for qualified installers only. Before beginning, make note of where the gas and electric

Page 42

MQRB6961 Locating Your Appliance All units are Factory Set for a Left Hand Burner System. Right Hand Burner System Requires Valve to be relocated to

Page 43

MQRB6961 See Thru Framing MQRB6961SK Kit is required for a See Thru Installation. Before you begin Framing- Determine whether the Wall Surface will b

Page 44

Wall Surface Flush With Face of Fireplace Framing Flush With Face of Fireplace Note: If using Optional Surround, Maximum Thickness for Non-

Page 45 - Using the Optional Surrounds

MQRB6961 Single Sided Framing An MQRB6961BK Kit is required for a Single Sided Installation. Before you begin Framing- Determine whether the Wall Surf

Page 46 - Surround Installation:

Wall Surface Flush With Face of Fireplace Framing Flush With Face of Fireplace Note: If using Optional Surround, Maximum Thickness for N

Page 47

MQRB6961 Combustible Enclosure Heights Cold Climate Recommendation When installing this fireplace against an exterior wall or chase, it is recommended

Page 48

Surround Dimensions MQRB6961 • The Surround Frames are 1” thick, with a 3/4” space behind the frame. • When using Surrounds, Maximum Thickness f

Page 49 - WARNING

MQRB6961 Facing Material Requirements These specifications are the same for all Models (6961N, 6961NE, 6961LP, 6961LPE). Note: If using Optional Surr

Page 50

MQRB6961 Mantel Clearances Before installing any mantels it is important to determine the combustibility of its material(s). There are two types of m

Page 51 - Door and Glass Information

Recommendations for Finishing of Clean View Linear Products  Only non-combustible materials may be used over the face of the appliance.  We recomme

Page 52

MQRB44BK / MQRB51BK / MQRB69BK Back Shield Kit –Single View *This Kit must be opened before unit is installed into Framing (See “Single Sided Framing”

Page 53 - Valve Access Cover Removal

Back Liner, False Bottom, and End Panel Installation: 1. Remove Liner Clips from the inside of the Firebox (Fig.1). 2. Place the Back Liner onto th

Page 54 - Gas Line Installation

MQRB44SK / MQRB51SK / MQRB69SK (See Thru Kit) Installation This basic Kit is required for See Thru installations. Note: To cover the Side Fillers wit

Page 55

MQRB4436 / MQRB5143 / MQRB6961 Liner & False Bottom Installation Single Sided: Back Liner, End Panel, and False Bottom Installation: 1. R

Page 56

MQRB4436 / MQRB5143 / MQRB6961 Liner & False Bottom Installation See Thru: False Bottom & End Panel Installation: 1. False Bottom Insert

Page 57 - -CAUTION

MQRB4436, MQRB5143 & MQRB6961 Finishing Options Using Side Fillers The Side Fillers are located at each side of the door. They are provided to

Page 58

MQRB4436 / MQRB5143 / MQRB6961 Surround Installation Surround Kits are available in 3 different finishes: MQRB4436 MQRB5143 MQRB6961 Small [1-1/2”]

Page 59 - ARNING!

Fan Installation MQRB4436 / MQRB5143 / MQRB6961 FAN KIT IS FOR USE IN BK (SINGLE SIDED) INSTALLATIONS ONLY Fan Kit should be installed before the fire

Page 60 - -Warning

Fan Speed Control Outside of Fireplace If you plan to locate the variable speed control switch for the fan outside of the fireplace and you require a

Page 61

MQRB4436 / MQRB5143 / MQRB6961 -Optional Glass Ember Installation If you wish to use this media evenly spread the glass embers onto the fa

Page 62 - Warning

Pre-installation Questions and Answers About curing of the paint Your stove or fireplace has been painted with the highest quality silicone stove pa

Page 63

Optional Driftwood & Rock Installation The following Driftwood and Decorative Rock kits are available for the Infinite Series. Model Part Number

Page 64

Door and Glass Information Glass Cleaning It will be necessary to clean the glass periodically. During startup, condensation, which is normal, forms o

Page 65

Infinite Series Door Latch Tool MQRB4436 / MQRB5143 / MQRB6961 A Door Latch Tool is provided to assist with removing and installing the glass

Page 66 - Remote Receiver Location

Valve Access Cover Removal Remove Valve Access Cover in order to access igniter and valve controls. To remove Valve Access Cover, simply insert finge

Page 67 - UHS must be used

Gas Line Installation This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CAN/CSA

Page 68

Millivolt System, Lighting, and Burner Control FOR YOUR SAFETY READ BEFORE LIGHTING BEFORE LIGHTING A This appliance has a pilot which must be ligh

Page 69

Troubleshooting the Gas Control System Problem Possible Causes Corrective Action Defective or misaligned electrode at pilot. Check for spark at

Page 70 - TO TURN OFF GAS

Burner System Maintenance- MQRB4436 / MQRB5143 / MQRB6961 It is recommended to annually inspect and clean the Burner System to prevent malfunction and

Page 71

Gas Conversion for Top Convertible Pilot (Series 019065X) – PART B Instructions for converting SIT 190 series pilot burner injection from NG to LPG

Page 72

Gas Conversion for Modulator – PART C -WARNING!- -WARNING!- 59

Page 73

Mobile Home/Manufactured Housing Installation This Direct Vent System Appliance must be installed in accordance with the manufacturer’s installation

Page 74 - IPI Photos

MQRB4436 Burner Section: Gas Conversion Models: MQRB4436N, MQRB4436LP, MQRB4436NE, MQRB4436LPE. Kit Number Description Pilot Orifice Burner Orifice

Page 75 - Inside of IPI Module

MQRB5143 Burner Section: Gas Conversion Models: MQRB5143N, MQRB5143LP, MQRB5143NE, MQRB5143LPE. Kit Number Description Pilot Orifice Burner Orifice

Page 76 - IPI Valve

MQRB4436 / MQRB5143 Burner Tube Removal 1. Remove the six [6] DT screws from the lower portion of the Burner Tube Mount Brackets. 2. Slide the Bur

Page 77 - Millivolt Valve

MQRB4436 / 5143 / 6961 Moving Valve to Other Side of Fireplace Warning: Failure to position the parts in accordance with these diagrams or failur

Page 78

MQRB6961 Burner Section: Gas Conversion Models: MQRB6961N, MQRB6961LP, MQRB6961NE, MQRB6961LPE. Kit Number Description Pilot Orifice Burner Orifice B

Page 79

MQRB6961 Burner Tube Removal 1. Remove the six [8] DT screws from the lower portion of the Burner Tube Mount Brackets. 2. Slide the Burner Tube awa

Page 80 - Venting

Remote Receiver Location For GT Series Remotes Only The Remote Receiver may be located inside of the unit- several inches to the left of the valve an

Page 81

51-UHS For Infinite Series MQRB4436, MQRB5143, MQRB6961 51-UHS can be inserted & removed from beneath fireplace through access panel

Page 82 - Use High Temperature Sealant

IPI Electronic Ignition SystemOverviewThe IPI system is an advanced burner controller thatprovides you with the option of having either aStanding-Pilo

Page 83 - Horizontal Vent Table

Electrical Supply in Series: The entire IPI system can be powered by a single power source (i.e. by the AC Adapter). This is advantageous if you do n

Page 84 - MQRB5143 Venting Examples

Warnings, Installations and Operations Installation Regulations This gas appliance must be installed by a qualified installer in accordance with local

Page 85 - 52-1/4”Min

Electronic Ignition Lighting Instructions If you do not follow these instructions exactly, a fire or explosion may result causing property damage, p

Page 86

IPI Electronic Ignition Parts List – Standard System Item No. Part No. Description 1 1006-P002si Valve IPI Hi/Lo NG 1006-P003si Valve IPI Hi/

Page 87 - Roof Flashing

EGTRC – Remote Control Thermostat (Not permitted for vented gas fireplaces installed in the U.S.A.) EGTMRCN or EGTMRCP – Remote Control Thermo

Page 88 - Flue Restrictor Adjustment

Configuration #3: Remote ON/OFF, variable HI/LO, and fan capabilities. Refer to the fan installation/removal section for fan inst

Page 89

IPI Photos Bottom of Unit with IPI Module Light Module &IPI Valve (MQRB5143 Shown) 74

Page 90

Close up View of IPI Module Inside of IPI Module 75

Page 91

IPI Valve IPI Valve 76

Page 92

Millivolt Valve & Light Module Millivolt Valve 77

Page 93 - PVH58 Venting Adapters

LK2 Halogen Lamp Kit MQRB4436 / MQRB5143 Please follow the current ANSI/NFPA 70 National Electrical Code in the USA and CAN/CSA C22.1 Canadian Nation

Page 94

LK3 Halogen Lamp Kit (MQRB6961) Please follow the current ANSI/NFPA 70 National Electrical Code in the USA and CAN/CSA C22.1 Canadian National Elect

Page 95 - PVH58 POWER VENT MOUNTING

• Gas fired appliances may be used only for supplemental heat and/or decorative purposes and under no circumstances shall they provide a primary heat

Page 96 - THE INSTALLATION

Venting A. Clearance above grade, veranda, porch, deck, or balcony 12in [30cm] min.[1,2] B. Clearance to window or door that may be opened. 12in [

Page 97

General Vent Installation Information This gas appliance is approved to be vented either through the side wall or vertically through the roof. Only Ki

Page 98

Figure 1 - Flex pipe spring spacing guide. Horizontal runs require support metal straps every 2ft. In an offset installation support straps sh

Page 99 - PVCM Schematic - Millivolt

Minimum clearance to combustibles on venting is 1” with the following exceptions: MQRB4436 MQRB5143 MQRB6961 Top of horizontal 2” 2” 2” Top of 9

Page 100 -

MQRB5143 Venting Examples Wall Thimble and Roof Support The Wall Thimble is used in horizontal installations to shield the combustible material from

Page 101 - REMOTE CONTROL, ETC

Installation of Side Wall Venting Vertical rise over 3ft horizontal run (MQRB5143 shown). Note that the minimum height from the bottom of fireplac

Page 102 - PVCM Schematic - IPI

Z57ST24 / Z57ST36 Horizontal Snorkel Terminations MQRB4436 / MQRB5143 -FOR INFINITE SERIES II MODELS ONLY- Two snorkel terminations are avail

Page 103

Venting Straight Up Through Roof An Attic Insulation Shield must be installed where the vent passes from a lower living space into an attic space w

Page 104

Flue Restrictor Adjustment MQRB4436 / MQRB5143 Only –All Models The Flue Restrictor is located in the top of the Firebox in front of the Flue Opening

Page 105 - !WARNING

71 Figure 4 - Clearances in horizontal venting. Figure 5 - a) Straight-through roof support configuration; b) Flex bend configuration; c) Terminat

Page 106 - PVH58 Parts List

MQRB4436 / MQRB5143 / MQRB6961 Nailing Tab Guide The Nailing Tabs on the MQRB4436, MQRB5143 or MQRB6961 can be used in two ways: 1/2” Drywall

Page 107

PVH58 INSTALLATION OVERVIEW The PVH58 Horizontal Power Vent is approved for the following models only: MQRB4436, MQRB5143, MQRB6961 Either Hard Pi

Page 108 - MQRB4436 -Parts List

PVH58 VENTING CLEARANCES A. Clearance above a veranda, porch, deck, or balcony or other combustible surface is 27”. Clearance above grade i

Page 109 - Venting Accessories

PVH58 VENTING HARD PIPE OR FLEX The PVH-58 Power Vent is approved for the following models only: MQRB4436, MQRB5143, MQRB6961 Refer to firepl

Page 110 - MQRB5143 -Parts List

PVH58 Venting Adapters ADAPTERS REQUIRED FOR HARD PIPE INSTALLATION Adapters Required At Fireplace MQRB4436, MQRB5143 Z57DFA MQRB6961 Z69DFA

Page 111

PVH58 VENTING CONFIGURATIONS MAX 3ft Below UnitMIN Venting= 3ft plus one 90° elbowwith Air Intake Shutter fully openMAX Venting = 125

Page 112 - MQRB6961-Parts List

PVH58 WALL THIMBLE INSTALLATION An 11 inch square opening is required. Center Wall Thimble over the 11 inch square opening and secure both pieces on e

Page 113

PVH58 Wiring Harness Connections WARNING WARNING WARNING A qualified electrician must connect electrical wiring to junction outle

Page 114 - IPI Remotes

PVH58 Millivolt System Connections WHITEBLACK GREEN/GRND BROWNRED 10ft Double Pole Switch Wiring Harness for Millivolt Systems. Connects t

Page 115 - Miscellaneous Parts

MILLIVOLT POWER VENT CONTROL MODULE Connect to Power Vent CableConnect to Double Pole Switch CablePlug into120v AC OutletConnect to TH and TH / T

Page 116

PVCM Schematic - Millivolt 99